Skip to content

Solahart 181L

181l_front

Solahart 181L

180lt Roof Top Solar System

Solahart's roof mounted tank systems save space at ground level and their elegant simplicity make them efficient and reliable. The Solahart 181L Series is a roof mounted, open circuit solar water heater specifically designed to provide economical service in medium to high solar gain areas. The smaller volume of the 181L makes it ideal for applications where low volumes of solar hot water are required, e.g. small units or retirees.

people-group-solid 1
Family size

180

Capacity (L)

1

Collectors

5yr

Warranty†

181L Roof Top Solar: Key Attributes

Optimal Performance

Most suitable for areas that receive medium to high levels of solar radiation and are not subject to frost conditions.

Ceramic Lined Tank

Corrosion protection for the water heater’s solar tank is obtained by using a proven, high quality vitreous enamel and a sacrificial anode.

Booster Options

The electric boosted models are equipped with an in-tank element. Alternatively the system can be installed as a pre-heater with an inline Solahart gas booster water heater.

Environmental Incentives

There is an incentive resulting in a financial benefit to households that install solar hot water, under the Renewable Energy Target – a Federal Government legislated scheme. Your Solahart Expert can deduct the value of the financial benefit as an upfront discount off your system.

The Solahart L Series is a roof mounted, open circuit solar water heater specifically designed to provide economical service in medium to high solar gain areas. It is not recommended for use in frost or poor water chemistry areas.

The L Series is ingenious in its simplicity. The black polyester powder coated aluminium absorber collects the sun's heat and transfers it to the water in the 7 risers. Copper is used for the risers for its high thermal conductivity ensuring the maximum amount of heat energy is passed to the water. As the water in the risers is heated, it rises into the tank to be replaced by cooler water from the tank. The solar heated water is then stored ready for use - hot water free from the sun.

Stylish slimline roof mount design

Reliable, low maintenance operation

Can cut water heating energy use by up to 60%^

Eligible for Government rebates and incentives

181sp

* The suggested price is comprised of RRP less the applicable solar incentive and excluding installation. Solar incentive value applies to 181L system in Zone 3.

^ Energy savings of up to 60% shown is based on Australian Government approved TRNSYS simulation modelling of a Solahart 181L and using a small load in Zone 3 and apply when replacing an electric water heater. Any savings will vary depending upon your location, type of Solahart system installed, orientation and inclination of the solar collectors, type of water heater being replaced, hot water consumption and fuel tariff. Maximum financial savings off your hot water bill are achievable when replacing an electric water heater on continuous tariff.

† Solahart Warranty Details: 5/5/5 warranty; 5 year cylinder and collectors supply, 5 year parts, 5 year labour.

How Roof Top Solar Systems Work

302l_operation-removebg-preview

Solar Operation

The 181L solar system has its vitreous enamel lined solar storage tank installed on the roof directly coupled to the solar collectors. It works on the simple scientific fact that hot water rises. As the sun heats the water in the solar collectors, the increase in temperature causes the water to rise through an insulated copper pipe into the storage tank. This allows cooler water from the solar storage tank to flow into the solar collectors to be heated by the sun‟s energy. This process continues while solar energy is available.

Orientation of Solar Collectors

To help maximise system performance, solar collectors should be installed with an optimum orientation facing true north (in the southern hemisphere) or true south (in the northern hemisphere). Always check for true north or true south using a compass or other suitable device.

To help maximise system performance, solar collectors should be installed with an optimum inclination. This is equal to 90% to 100% of the local latitude angle when collectors are oriented within 60° of true north or true south, and between 10° and 20° if the collectors are oriented between 60° and 90° from the optimum orientation. Generally, improved summer performance is obtained from an angle of inclination less than the optimum angle and improved winter performance is obtained by an angle of inclination greater than the optimum angle. If the angle of inclination varies by 20° from the optimum angle, the solar collectors will receive about 10% less total annual solar radiation.

picture1 (1)

Frost/Freeze Protection

An Open Circuit system does not have freeze protection and is not suitable for installation in areas prone to freeze conditions. Freeze conditions occur below 5°C (41°F). This system has NO WARRANTY for freeze damage. In areas that are prone to frost / freezing, a Closed Circuit system should be used.

solar boosting

In-Tack boosting

An isolating switch is installed in the electrical meter box for an electrically in-tank boosted model. This should be left switched on to allow the booster heating unit to operate if required. The booster heating unit is for heating the water at times of low solar energy gain, such as during very cloudy or rainy weather, or during the colder months. The booster heating unit will only activate if heating is required and power is available from the switchboard. When the water is below the thermostat setting, the booster heating unit will turn on and heat the water. The booster heating unit will automatically turn off when the temperature of the water reaches the thermostat setting. If the water temperature drops below the setting again the booster will re-activate.

feature_images_booster_235x166_x2 (1)

In-Series Gas Boosting

An in-series gas booster (also known as a continuous flow gas booster) can be installed between the solar water heater and the hot outlets in the house. This booster should be permanently active. The booster senses the temperature of the water passing through it: if the water temperature is above its temperature setting it does nothing; if below it will automatically heat the water up to the preset outlet temperature setting. This gas booster ensures hot water delivery for a variety of hot water demands without the need for user intervention while enabling maximum solar energy contribution to the water heating. For more information on this booster, consult the owner’s manual for the product.

Over-Temperature Protection System

The Open Circuit Series systems may be installed with a ‘TRV’ located between the cold inlet of the tank and the cold inlet of the collectors. This valve restricts the flow through the collectors when the tank has reached a sufficiently high temperature.

Book Your Free In-Home Consultation!

Scroll To Top